Building Performance Diagnostics · South London · SE15

Building Performance Diagnostics in Peckham

Peckham is a fast-changing SE15 neighbourhood of Victorian terraces, large council estates and period conversions, with a substantial rented sector. Condensation, mould and cold solid-wall homes dominate, and we tackle them with measurement and remediation.

One company, the whole process

Investigation only, remedial works, or a complete retrofit — your choice.

RetrofitIQ is not only a diagnostics company. We take projects from first investigation through to verified improvement — and you decide how far we go. Engage us for an investigation on its own, for an investigation plus targeted remedial works, or for a complete building-performance and retrofit project in Peckham.

Investigate
Diagnose
Design
Remediate
Verify
Remediation & retrofit works we can carry out
  • Airtightness improvements & draught-proofing
  • Internal wall insulation (IWI)
  • External wall insulation (EWI)
  • Loft & roof insulation
  • Suspended floor & underfloor insulation
  • Thermal-bridge detailing & correction
  • Extract ventilation & MVHR installation
  • Soundproofing & acoustic upgrades
  • General building-fabric improvements
Local building stock · Peckham

The buildings of Peckham, and how they perform.

Peckham's terraces are solid-wall with suspended floors and rear additions, widely converted into flats and let as HMOs. Its estates bring concrete-framed blocks with thermal bridges; high occupancy and limited ventilation push humidity to mould-forming levels.

Typical properties in Peckham
  • Victorian solid-wall terraces
  • Period houses converted into flats
  • Concrete-framed council estates
  • Landlord-let flats and HMOs
  • New-build infill apartments

Thermal Imaging Surveys in Peckham

In Peckham, thermal imaging shows whether mould is driven by cold surfaces, missing insulation or poor ventilation.

  • Mapping heat loss through walls, roofs and floors
  • Locating missing, slumped or incomplete insulation
  • Identifying thermal bridging and cold spots
  • Highlighting surfaces at risk of condensation
  • Revealing hidden defects behind finishes

Damp, Condensation & Mould Investigations in Peckham

Our measured condensation and mould investigations give Peckham landlords and owners a defensible diagnosis and fix.

  • Separating condensation from penetrating and rising damp
  • Finding mould behind wardrobes, furniture and in cold corners
  • Measuring relative humidity, surface temperature and dew point
  • Assessing ventilation provision and moisture sources
  • Combining thermal imaging with a building-physics review

Heat Loss & Energy Efficiency Surveys in Peckham

Solid walls, floors and lofts lead loss in the terraces; floor-slab bridges lead it in the estates.

  • Pinpointing where heat escapes — walls, floors, roofs, windows and doors
  • Setting fabric-first retrofit priorities in the right order
  • Quantifying the impact of each potential improvement
  • Assessing heat pump readiness where relevant
  • Producing a clear, costed improvement plan

Blower Door Testing & Airtightness in Peckham

Blower door testing quantifies draughts across Peckham's converted and let stock.

  • Measuring air leakage and uncontrolled heat loss (ACH₅₀)
  • Locating draughts with smoke tracing
  • Identifying leakage paths through floors, lofts and services
  • Guiding targeted airtightness improvements
  • Verifying performance before and after retrofit works

Retrofit & Building Physics Advice

We can install effective ventilation, insulate cold surfaces and verify that humidity and comfort improve.

  • A fabric-first, Passive House-informed approach
  • Retrofit advice aligned with PAS 2035 principles
  • Internal and external wall insulation risk assessment
  • Thermal-bridge reduction and condensation-risk modelling
  • A coherent ventilation strategy to protect health and fabric
What we see locally

Common building performance problems in Peckham.

Black mould in converted and let flats with poor ventilation
Condensation streaming down windows in winter
Cold external walls and corners in solid-wall homes
Cold concrete bridges in estate flats
Heat loss through uninsulated walls, floors and lofts
Inadequate bathroom and kitchen extraction
Damp at low level on solid walls misread as rising damp
Why choose RetrofitIQ

A technical, building-physics-led specialist in Peckham.

Certified Passive House Designer
Building-physics-led diagnostics
FLIR thermal imaging
Calibrated moisture readings
Blower door / airtightness testing
Clear, costed reports and recommendations
End-to-end: investigation through to verified works
Fully insured, London-based specialists
Building performance in Peckham — in depth

Peckham’s architectural landscape is one of South London’s most diverse, spanning from the elegant, leafy Victorian terraces around the Bellenden Road area to mid-century housing estates and rapidly expanding modern high-density developments. However, beneath the character of SE15 lies a complex web of building performance challenges. Whether you reside in a draughty 19th-century townhouse suffering from chronic heat loss, a subdivided flat conversion plagued by noise transmission, or a newly built apartment experiencing severe summer overheating and poor indoor air quality, generic building surveys rarely provide the deep diagnostic insights required to actually solve these issues.

RetrofitIQ provides advanced, building-physics-led home health diagnostic surveys across Peckham and the wider Southwark borough. Led by a Certified Passive House Designer, our on-site investigations move far beyond the guesswork of traditional damp proofing companies or basic EPC assessments. We utilise forensic building science—incorporating blower door testing, high-resolution thermal imaging, and detailed hygrothermal analysis—to understand exactly how your property manages heat, air, and moisture.

Our mission is to help Peckham homeowners, landlords, and architects design targeted, fabric-first retrofits. By identifying the root causes of black mould, persistent draughts, cold bridges, and uneven room temperatures, we deliver independent, scientifically backed retrofit strategies that transform uncomfortable, energy-hungry properties into healthy, resilient, and ultra-efficient homes.

The Complex Dynamics of Peckham’s Housing Stock

Peckham is a microcosm of London’s architectural evolution, and understanding how these distinct eras of construction perform thermally and hygroscopically is the foundation of any successful retrofit. The SE15 postcode is heavily defined by its 19th-century heritage—expansive networks of Victorian and Edwardian terraces, built with 9-inch solid brick walls, suspended timber floors over London clay, and slate or clay tile pitched roofs. These heritage properties were fundamentally designed to 'breathe'. They relied on open coal fires to drive massive amounts of air changes per hour, pulling moisture out of the building fabric, while the lime-based mortars and plasters allowed vapour to naturally diffuse.

When we conduct building performance investigations in Peckham’s historic homes, we almost universally find that this delicate hygrothermal balance has been disrupted. Open fireplaces have been sealed, original sash windows replaced with airtight (but unventilated) uPVC units, and breathable lime pointing replaced with hard, impervious Portland cement. The result is a building envelope that traps moisture. Because the modern family generates upwards of 10 to 15 litres of water vapour a day through cooking, washing, and breathing, this moisture has nowhere to go. It seeks out the coldest surfaces—typically the uninsulated solid walls or window reveals—leading to condensation, high indoor humidity, and black mould.

In contrast, Peckham’s mid-century housing blocks and newer regeneration developments present an entirely different set of building physics challenges. Mid-century concrete-framed properties frequently suffer from systemic cold bridging. Balconies, walkways, and concrete lintels act as thermal highways, drawing heat out of the flat and providing extremely cold internal surfaces where mould thrives. Modern apartments built in the last two decades are generally more airtight and better insulated, but they frequently suffer from poor indoor air quality and severe summer overheating. Single-aspect flats in dense urban environments lack the cross-ventilation necessary to flush out hot air and volatile organic compounds (VOCs). Assessing a property in Peckham requires an acute awareness of these specific construction typologies; an energy retrofit strategy that works for a 2015 apartment on Queens Road will cause catastrophic failure if applied to a Victorian terrace on Choumert Road.

Forensic Damp, Condensation & Black Mould Diagnostics

One of the most persistent issues driving homeowners to seek a building performance investigation in Peckham is the presence of damp and black mould. The traditional response in the UK has often been to call a 'damp proofer', which frequently results in a diagnosis of rising damp and a quotation for injected chemical damp proof courses (DPCs) and waterproof cement renders. Through the lens of building physics, this approach is often fundamentally flawed, particularly in historic solid-walled properties.

Our damp and moisture investigations focus on the actual mechanics of water transport: capillary action, vapour diffusion, and air leakage. True rising damp is exceedingly rare. What we typically diagnose during a damp survey in SE15 is either penetrating damp (driven rain bypassing failed pointing, blocked gutters, or bridging of the external ground level over the original DPC) or, far more commonly, severe condensation driven by high relative humidity and low surface temperatures.

By deploying hygrometers, thermal imaging cameras, and conducting dew point analysis, we can pinpoint exactly why a wall is damp. In many Peckham properties, black mould on a bedroom wall is not a moisture ingress problem; it is a thermal performance and ventilation problem. When indoor relative humidity routinely exceeds 60-70 per cent, and the internal surface temperature of a solid brick wall drops below the dew point (often around 10-12°C in winter), water vapour condenses invisibly within the microscopic pores of the plaster. Over time, this surface dampness supports fungal growth. If a previous owner has applied non-breathable internal wall insulation (IWI) without a continuous vapour control layer, the moisture may be trapped inside the wall assembly itself—a phenomenon known as interstitial condensation. Our surveys identify these hidden failures, allowing us to recommend solutions that address the root hygrothermal cause rather than merely masking the symptoms.

Airtightness and Blower Door Testing in SE15

A cold home in Peckham is rarely just the result of poor insulation; it is almost always heavily influenced by uncontrolled air infiltration, commonly known as draughts. Heat loss through air leakage can account for up to 30-40 per cent of a property's total energy demand. Traditional energy performance certificates (EPCs) make crude assumptions about a building's air permeability, but an on-site building physics investigation measures it precisely using a blower door test.

A blower door test involves temporarily sealing an external door with a specialized fan system that depressurises or pressurises the house. This forces air through every crack, gap, and unseen thermal bypass in the building envelope. When conducting air leakage investigations in Peckham’s Victorian terraces, the results are often striking. We frequently trace massive volumes of cold air being drawn up from the ventilated sub-floor void through gaps between exposed floorboards and poorly sealed skirting boards. We also find significant air leakage around structural joist ends embedded in masonry, unsealed loft hatches, redundant chimneys, and poorly integrated window frames.

This uncontrolled ventilation does more than just cause a cold draught across your ankles; it undermines the performance of any insulation you have installed. For instance, if cold air can freely bypass loft insulation by travelling up an unsealed cavity or behind plasterboard drylining (a phenomenon known as thermal looping), the U-value of that insulation is drastically reduced. Blower door testing allows us to quantify the air permeability of your home and physically locate the leakage pathways. This data is critical for planning a 'fabric-first' retrofit, enabling targeted draught-proofing that reduces heating bills and improves thermal comfort without compromising the necessary background ventilation of the home.

Thermal Imaging & Heat Loss Investigations

Understanding precisely where a building is losing heat requires more than a visual inspection. RetrofitIQ employs high-resolution thermal imaging as a core component of our heat loss surveys across Peckham. An infrared camera visualises surface temperature differentials, providing a non-destructive x-ray of the building envelope's thermal performance.

When we conduct thermal imaging surveys on cold winter mornings in SE15, we are looking for specific thermal anomalies. In historic properties, thermal imaging routinely reveals missing or slumped insulation within roof slopes, uninsulated dormer cheeks, and the stark thermal bridges created by solid masonry party walls extending into unheated loft spaces. We also frequently identify 'cold corners' where geometric thermal bridging occurs—areas where two external walls meet, significantly increasing the heat loss area relative to the internal surface.

In mid-century construction and more recent Peckham developments, thermal imaging is invaluable for diagnosing building fabric failure. We can identify poorly installed cavity wall insulation (where gaps in the fill create localised cold spots highly prone to black mould), continuous concrete floor slabs that project outward to form balconies (creating a massive radiator effect that pumps heat directly out of the building), and missing insulation around steel lintels. By combining thermal imaging with blower door depressurisation, we can also visually track cold air plumes entering the building envelope. This empirical data ensures that our retrofit designs and insulation strategies are targeted precisely where they will yield the greatest energy savings and comfort improvements, eliminating the guesswork from home energy upgrades.

Insulation Strategies and Overcoming Thermal Bridging

Upgrading the thermal envelope of a Peckham property requires a nuanced approach, heavily influenced by the specific construction era. The goal of a deep energy retrofit—or a step-by-step PAS 2035 aligned retrofit plan—is to lower U-values (reduce heat loss) while meticulously managing moisture risk and mitigating thermal bridges.

For the vast majority of Peckham’s Victorian and Edwardian terraces, External Wall Insulation (EWI) is often restricted on front elevations due to conservation rules or the desire to preserve the historic brick façade. In these cases, Internal Wall Insulation (IWI) is the primary pathway. However, applying standard closed-cell rigid foam boards (like PIR) directly to solid brickwork introduces high hygrothermal risks. Because the brickwork becomes colder (as it is no longer heated from the inside), it cannot dry out as quickly after driving rain. If a perfect vapour control layer is not maintained internally, moisture will become trapped behind the insulation, leading to unseen rot and structural degradation. Our retrofit design approach typically advocates for capillary-active, vapour-permeable insulation systems—such as wood fibre boards or cork, finished with lime plaster. These materials actively manage moisture, safely storing and releasing it, preserving the health of the historic fabric.

Thermal bridging is another critical consideration. A thermal bridge is an area of the building envelope that has significantly higher heat transfer than the surrounding materials. Common examples in local homes include the junction where internal solid masonry walls meet the cold external wall, or where structural floor joists penetrate the external envelope. If you heavily insulate the main walls but ignore these junctions, you concentrate the heat loss and moisture risk precisely at these cold spots, creating a highly localised environment for heavy condensation and mould. Our building physics assessments model these junctions to design continuous thermal envelopes—utilising strategies like insulating the internal returns of party walls and addressing floor voids—to deliver Passive House levels of comfort and resilience.

Ventilation Assessments and Indoor Air Quality

A crucial maxim in building physics and retrofit design is 'build tight, ventilate right'. As we draught-proof and insulate homes across Peckham to lower heating bills and eliminate cold draughts, we inherently reduce the incidental, uncontrolled air infiltration that previously diluted indoor pollutants and moisture. Without a dedicated, engineered ventilation strategy, a well-insulated home will quickly suffer from high indoor humidity, condensation, and poor indoor air quality.

Peckham’s urban environment complicates natural ventilation. Given the proximity to busy thoroughfares like Queens Road, Peckham High Street, and the Overground railway lines, relying on open windows for ventilation (purge ventilation) is often undesirable due to noise, dust, and vehicle exhaust particulates (PM2.5 and NOx). Therefore, a robust ventilation assessment is a mandatory component of our home health diagnostic surveys.

For most deep retrofits in the area, we evaluate the feasibility of continuous Mechanical Extract Ventilation (cMEV) or, ideally, Mechanical Ventilation with Heat Recovery (MVHR). An MVHR system continuously extracts stale, moisture-laden air from kitchens and bathrooms, passing it through a heat exchanger to warm incoming, filtered fresh air supplied to bedrooms and living spaces. This guarantees exceptional indoor air quality, radically lowers relative humidity to banish condensation and mould, and recovers up to 90 per cent of the heat that would otherwise be lost. Our surveys assess the ducting pathways, acoustic implications, and air volume requirements necessary to integrate these systems into both historic retrofits and modern apartment upgrades.

Acoustic Flooring and Soundproofing in Dense Urban Environments

In a densely populated area like Peckham, acoustic privacy is a fundamental aspect of building performance and home comfort. Many of the large Victorian and Edwardian properties in SE15 have been subdivided into flats over the decades. These conversions frequently failed to upgrade the acoustic separation between floors and party walls, leading to significant distress from noise transmission.

Soundproofing must be approached through the lens of building physics, as noise travels via both airborne transmission (voices, television, music) and impact transmission (footsteps, moving furniture). The suspended timber floors common in Peckham’s period homes act like a drum, easily transmitting impact noise through the joists and into the ceiling below, while airborne sound readily passes through the gaps in floorboards and uninsulated voids.

RetrofitIQ incorporates acoustic assessments into our broader building performance methodology. Effective soundproofing requires mass, decoupling, and damping. For floor upgrades, this often involves lifting the existing floorboards to install high-density acoustic mineral wool between the joists (to reduce the resonance cavity and block airborne sound). We then design decoupled acoustic flooring systems—using resilient acoustic batten systems or heavy dense acoustic underlays combined with mass-loaded vinyl—to physically break the vibration path between the finished floor and the structural joists. Furthermore, we must carefully detail the perimeter to prevent 'flanking transmission', where sound travels down the rigid solid masonry walls, bypassing the floor structure entirely. By integrating acoustic upgrades with underfloor thermal insulation, we deliver a holistic improvement to the living environment.

Mitigating Summer Overheating in Modern Peckham Flats

While much of retrofit focuses on keeping homes warm in winter, a rapidly growing building performance crisis in London is summer overheating. Peckham is subject to a significant Urban Heat Island (UHI) effect, where dense infrastructure, lack of vegetation, and waste heat from transport and buildings cause localised temperatures to soar well above suburban or rural baselines.

This issue is particularly acute in the modern, recently constructed apartment blocks and high-density infill developments around SE15. Many of these newer flats are highly insulated and airtight, but suffer from poor solar shading, extensive south- or west-facing glazing, and single-aspect layouts that make cross-ventilation impossible. During a summer heatwave, solar radiation enters through the glazing and becomes trapped inside the heavily insulated envelope. Because the external night-time temperatures in Southwark rarely drop low enough to provide effective passive cooling, the internal temperatures compound day after day, leading to severe thermal discomfort and health risks.

Our building physics assessments utilise overheating analysis to diagnose and mitigate these risks. We evaluate the g-value (solar transmittance) of existing glazing, the building's thermal mass, and ventilation rates. Mitigation strategies in these urban settings often require a combination of external solar shading (internal blinds are largely ineffective as the heat has already entered the thermal envelope), the application of advanced solar control window films, and the design of dedicated mechanical cooling or enhanced purge ventilation systems via MVHR bypass modules. Addressing overheating is a critical component of ensuring a property is resilient to a changing climate.

The Passive House Approach and EnerPHit Retrofit Design

For Peckham homeowners looking to achieve the ultimate standard in energy efficiency, comfort, and indoor air quality, RetrofitIQ provides expert guidance on Passive House (Passivhaus) principles and the EnerPHit standard (the Passive House certificate for retrofits). Achieving EnerPHit in a historic London terrace is exceptionally challenging, but applying its underlying building physics principles is the most rigorous way to guarantee a successful whole-house retrofit.

The EnerPHit approach demands absolute continuity of the thermal envelope, rigorous airtightness, high-performance triple-glazed windows, and mechanical ventilation with heat recovery. Even if full certification is not the goal, utilizing the Passive House Planning Package (PHPP) software allows us to model a property’s precise energy balance. PHPP energy modelling goes lightyears beyond the basic algorithms of an EPC. It accounts for local Peckham climate data, the specific orientation of your home, shading from neighbouring buildings, and the exact U-values of your proposed insulation materials.

By designing a retrofit through PHPP, we can mathematically predict your future heating demand, eliminate the risk of interstitial condensation, and accurately calculate the return on investment for different fabric upgrades. As a consultancy led by a Certified Passive House Designer, RetrofitIQ brings this exacting, science-driven methodology to every investigation and design project, ensuring that your retrofit budget is deployed where it will have the maximum verifiable impact.

Why Choose RetrofitIQ’s Independent Building Experts in Peckham

The retrofit and damp industry is unfortunately saturated with vested interests. Contractors offering 'free surveys' are invariably salespeople whose ultimate goal is to sell you a specific product—be it chemical damp proofing, basic cavity wall insulation, or proprietary ventilation units—regardless of whether it is the correct building physics solution for your specific property.

RetrofitIQ is fiercely independent. We do not sell insulation materials, damp chemicals, or installation services. We sell objective, high-level building physics expertise. When you commission a home health diagnostic survey or retrofit assessment with us in Peckham, you are engaging a senior building performance specialist whose only priority is the long-term health, efficiency, and structural integrity of your home.

Our comprehensive, on-site investigations map out the complex interactions between heat, air, and moisture specific to your property. We provide highly detailed, jargon-free diagnostic reports that explain the root causes of any defects, followed by actionable, fabric-first remediation designs. Whether you are dealing with a cold, mouldy bedroom in a 1960s local authority flat, seeking acoustic peace in a subdivided Victorian terrace, or planning a deep EnerPHit retrofit of a family home, RetrofitIQ provides the authoritative roadmap required to upgrade your Peckham property safely and successfully.

Peckham — frequently asked questions
Why are the walls in my Victorian terrace in Peckham so cold, and can I insulate them?+

Victorian terraces in Peckham were built with solid 9-inch brick walls, which offer very little thermal resistance (high U-values). They act as 'heat sinks', drawing warmth out of your home. You can insulate them, but it must be done carefully. Standard rigid foam (PIR) can trap moisture and cause the brickwork to degrade. We recommend a building physics assessment to design an Internal Wall Insulation (IWI) system using vapour-permeable, capillary-active materials like wood fibre, which keeps the wall warm while allowing it to safely breathe.

We have black mould in our mid-century flat in SE15. Is this rising damp?+

No. True rising damp is exceptionally rare, particularly in mid-century or elevated flats. The black mould you are seeing is almost certainly caused by surface condensation. Mid-century concrete-frame buildings in Peckham often have severe 'cold bridges' at structural junctions (like balconies or lintels). When warm, humid indoor air meets these cold surfaces, it condenses, providing the perfect environment for black mould. A home health diagnostic survey can calculate the dew point and specify targeted insulation and mechanical ventilation to cure the problem.

Why does my ground floor in Peckham feel so draughty?+

Most historic homes in SE15 feature suspended timber ground floors built over a void on London clay. To prevent timber rot, airbricks provide cross-ventilation to the sub-floor void. However, if the floorboards above are uninsulated and poorly sealed, this cold, damp air is drawn directly into your living space due to the 'stack effect' (warm air rising and escaping through the roof, pulling cold air up from the floor). A blower door test easily quantifies this leakage, allowing us to specify airtight underfloor insulation strategies.

Will replacing my old sash windows solve my condensation problem?+

Not necessarily; in fact, it can sometimes make it worse. Old sash windows are very draughty, providing high rates of uncontrolled air changes. If you replace them with modern, airtight uPVC or timber casements without simultaneously upgrading your home's purposeful ventilation (such as adding continuous mechanical extract ventilation), the moisture generated from cooking and showering is suddenly trapped indoors. This raises the relative humidity and shifts the condensation onto your cold external walls. Retrofit requires a holistic approach: 'build tight, ventilate right'.

What does a thermal imaging survey in Peckham actually show?+

A thermal imaging (infrared) survey visualises heat loss and surface temperature differentials across your building envelope. In Peckham homes, it helps us identify missing, slumped, or poorly installed loft and wall insulation, hidden thermal bypasses (where cold outdoor air gets behind plasterboard), structural thermal bridges, and even hidden areas of dampness (since wet materials have different thermal properties than dry ones). It is best conducted in winter when there is a significant temperature difference between indoors and outdoors.

Is MVHR suitable for an old Victorian house in SE15?+

Yes, Mechanical Ventilation with Heat Recovery (MVHR) is the gold standard for indoor air quality and energy efficiency, but it requires careful design. To be efficient, the house must first be made highly airtight (which we test via blower door). Retrofitting the ducting into a historic Peckham property requires planning to navigate solid joists and historic features. Our MVHR assessments determine the feasibility, optimal duct routes, and acoustic requirements to ensure the system is virtually silent.

How can I stop the noise from the flat upstairs?+

Many Victorian houses in Peckham have been converted into flats with inadequate soundproofing between floors. You are likely experiencing both impact noise (footsteps vibrating the joists) and airborne noise (voices travelling through gaps). Effective acoustic flooring requires decoupling (physically separating the floor surface from the joists using resilient layers), adding mass, and installing acoustic damping materials within the floor void. We assess the flanking transmission paths (noise travelling down the walls) to design a comprehensive acoustic upgrade.

Why is my modern apartment in Peckham overheating in summer?+

Modern apartments built in South London over the last twenty years are generally highly insulated and very airtight, but frequently feature large areas of glazing and single-aspect layouts. This creates a greenhouse effect: solar radiation enters the flat, generates heat, and cannot escape. Combined with the urban heat island effect in SE15 and a lack of cross-ventilation, internal temperatures can become dangerous. Overheating analysis can identify targeted solutions like external solar shading and mechanical purge ventilation.

Can I get Passive House certification for my existing home in Southwark?+

You can aim for the EnerPHit standard, which is the Passive House certification tailored specifically for retrofits. Achieving this in a traditional Southwark masonry property is an ambitious and deep engineering challenge, requiring external or complex internal wall insulation, exceptional airtightness, and triple glazing. Even if full certification isn't feasible, RetrofitIQ uses the Passive House Planning Package (PHPP) to apply these rigorous building physics principles, ensuring your retrofit performs to the absolute highest possible standard.

Get started in Peckham

Book a Building Performance Survey in Peckham.

Request a thermal imaging, damp, condensation or heat loss investigation — or speak to us about a full retrofit. We diagnose by measurement and, where you want it, carry out and verify the works.